5 thoughts on “What is the safety distance of gas pipelines?”

  1. "5 meters"
    5 meters. The "Petroleum and Natural Gas Pipeline Protection Law of the People's Republic of China" stipulates that: within the five meters of regions on both sides of the center line of the pipeline line, the following behaviors that are harmful to pipelines are prohibited: (1) planting trees, shrubs, vines, reeds, bamboo or other other The deep -reaching pipeline burial site may damage the deep -rooted plants of the anticorrosive layer of the pipeline;

  2. According to the requirements of the GB50028 of the "Urban Gas Design", the level of the level of the gas metering table and the gas stove must not be less than 300mm, and the net distance from the wall must not be less than 10mm after the surface. The net distance between the table should not be less than 150mm.
    If when installing the gas stove, it should be noted that the net distance from the metal chimney should not be less than 1.0m, and the net distance from the level of the brick chimney should not be less than 0.8m. When meeting the above requirements, the heat insulation board should be added.

  3. Pay content for time limit to check for freenAnswer dear, hello, the safe distance between the gas pipe and the sewage pipeline, the parallel safety distance is one meter.nTeacher Xiaocheng adds it to pay attention to details: 1) High -pressure and medium -pressure A gas pipes should be used for steel pipes; mid -pressure B and low -pressure gas pipelines should be used, and steel pipes or mechanical interface cast iron pipes should be used. When the middle and low -pressure underground gas pipelines adopt a polymer -B dilute pipe, it shall comply with the relevant standards. 2) Underground gas pipelines must not pass through the buildings and large structures. Underground gas pipelines and buildings, the level and vertical cleanliness between the structure of the structure or the adjacent pipeline should not be less than the relevant regulations. 3) The minimum soil thickness (road to the top of the pipe) buried underground gas pipelines shall meet the following requirements: when buried under the lane, it shall not be less than 0.9m; When buried in the courtyard, it shall not be less than 0.3m; when buried under the paddy field, it shall not be less than 0.8m (when the effective protection measures are taken, the above provisions can be appropriately reduced). 4) Underground gas pipelines must not be traveled under the venue of flammable, explosive materials and corrosive liquids, and should not be laid with other pipes or cables. When laid the same trench, protective measures must be taken.nI hope you can help you. May your life happy, happy family, good luck every day.n1 morenBleak

  4. The distance between the pipeline of oxygen pipeline and the commercial households is two meters away, and the distance is dangerous when the distance is too close.